G5LE
PCB Power Relay
Cubic, Single-pole 10A Power
Relay
• Ideal for a wide variety of applications such as home appliances, OA
equipments, vending machines, etc.
• Ambient Operating Temperature 85°C
• UL class-B coil insulation for standard model.
• UL, CSA, EN standards approved and conforms to Electrical
Appliance and Material Safety Law (300 V max.).
RoHS Compliant
■Model Number Legend
■Application Examples
G5LE- @ @@ -@ -@
——— — —
1 2 3 4 5
1. Number of Poles
1: 1-pole
4. Insulation System
None: Class B (Class F for -E versions)
CF: Class F (UL and CSA only)
5. Approved Standards
None: Standard
E:
High capacity type
2. Contact Form
None: SPDT (1c)
A:
SPST-NO (1a)
3. Enclosure rating
None: Flux protection
4:
Fully sealed
• Home appliances
• OA equipments
• Vending machines
G
5
L
E
■Ordering Information
Terminal Shape
Enclosure rating
Contact form
Classification
SPDT (1c)
Standard
PCB terminals
SPST-NO (1a)
SPDT (1c)
High capacity
SPST-NO (1a)
Flux protection
Model
Rated coil voltage
5 VDC
12 VDC
G5LE-1
24 VDC
5 VDC
G5LE-1-CF
12 VDC
24 VDC
5 VDC
G5LE-1A
12 VDC
24 VDC
5 VDC
G5LE-1A-CF
12 VDC
24 VDC
5 VDC
G5LE-1-E
12 VDC
24 VDC
5 VDC
G5LE-1A-E
12 VDC
24 VDC
Fully sealed
Rated coil voltage
5 VDC
12 VDC
G5LE-14
24 VDC
5 VDC
G5LE-14-CF
12 VDC
24 VDC
5 VDC
G5LE-1A4
12 VDC
24 VDC
5 VDC
G5LE-1A4-CF
12 VDC
24 VDC
Model
Minimun
packing unit
100 pcs/tray
---
---
Note. When ordering, add the rated coil voltage to the model number.
Example: G5LE-1 DC5
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.
■Ratings
Item
Contact type
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Classification
Load
Standard type
Resistive load
Inductive load (cosφ=0.4)
Single
Ag-alloy (Cd free)
10 A at 120 VAC, 8 A at 30 VDC
5 A at 120 VAC, 4 A at 30 VDC
10 A
250 VAC, 125 VDC (30 VDC when UL/CSA standard is applied)
10 A
5A
High capacity type
Resistive load
16 A at 250 VAC (NO)
12 A at 250 VAC (NC)
16A (NO)/12A (NC)
250 VAC
16A (NO)/12A (NC)
1
G5LE
PCB Power Relay
■Characteristics
Item
Contact resistance *1
Operate time
Release time
Insulation resistance *2
Dielectric strength
Impulse withstand
voltage
Vibration resistance
Shock resistance
Durability
Classification
Between coil and
contacts
Between contacts of the
same polarity
High capacity type
2,000 VAC, 50/60 Hz for 1 min
750 VAC, 50/60 Hz for 1 min
between coil and contacts 4,500 V (1.2×50 μs)
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
Failure rate (P level) (reference value) *3
Ambient operating temperature
Ambient operating humidity
Weight
G
5
L
E
Standard type
100 mΩ max.
10 ms max.
5 ms max.
100 MΩ min.
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
1,000 m/s2
100 m/s2
10,000,000 operations min. (at 18,000 operations/hr)
50,000 operations min. (NO)
100,000 operations min.
30,000 operations min. (NC)
(at 1,800 operations/hr)
(at 1,800 operations/hr)
100 mA at 5 VDC
-25°C to 85°C (with no icing or condensation)
35% to 85%
Approx. 12 g
Note. The data given above are initial values
*1. Measurement conditions: 5 VDC, 1 A, voltage drop method.
*2. Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured.
*3. This value was measured at a switching frequency of 120 operations/min.
2
G5LE
PCB Power Relay
■Engineering Data
●Durability
50
30
AC resistive
load
AC inductive
(cosφ 0.4)
10
7
5
3
● Ambient Temperature vs.
Maximum Coil Voltage
500
Maximum coil voltage (%)
Durability (x104 operations)
Switching current (A)
●Maximum Switching Capacity
300
30 VDC
resistive load
100
70
50
120 VAC
resistive load
30
200
180
160
140
1
0.7
0.5
10
7
5
DC resistive
load
0.3
0
120
3
10
30
50
100
500 1,000
0
250 VAC resistive load
120 VAC inductive
(cosφ = 0.4)
2
4
6
Switching voltage (V)
8
100
10
0
−25
12
20
30
40
50
Switching current (V)
60
70
80
90 100
Ambient temperature (°C)
Note. The maximum coil voltage refers to the maximum
value in a varying range of operating power
voltage, not a continuous voltage.
●Shock Malfunction
NO contact
Y
1,000
NC contact
1,000
X
G
5
L
E
1,000
Z’
500
Z Y
Z
1,000
500
X’
1,000
Y’
X’
Z’
X
1,000
Y’
Unit: m/s
2
Shock direction
Number of Relays:5 pcs
Test Conditions: Shock was applied 3 times in
each direction with and without
excitation and the level at which
the shock caused malfunction
was measured.
Rating:
100 m/s2
■Dimensions
G5LE-1 (-@) (SPDT contact)
G5LE-1A (-@) (SPST-NO contact)
(21.6)*
22.5 max.
Terminal Arrangement/
Internal Connections
(Bottom View)
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm unless
specified
(15.6)*
16.5 max.
SPDT (1c)
SPDT (1c)
Five,1.3+0.2
0 dia. holes
(18.56)*
19.0 max.
(2.25)
2
3
5
4
0.5
12
1
3.5
0.2
1
1.2
*Average value
0.4
12.2
(2.55) 2
(5.75)
(2.25)
(Indicates average dimensions.)
G5LE-14 (-@) (SPDT contact)
G5LE-1A4 (-@) (SPST-NO contact)
(21.6)*
22.5 max.
SPST-NO (1a)
(15.6)*
16.5 max.
SPST-NO (1a)
Four,1.3+0.2
0 dia. holes
(2.25)
(18.5)*
19.0 max.
12
2
3
1
5
0.5
12.2
3.5
(2.55) 2
0.2
1
1.2
*Average value
(5.75)
(2.25)
(Indicates average dimensions.)
0.4
Note. Orientation marks are indicated as follows:
3
G5LE
PCB Power Relay
■Approved Standards
UL Recognized:
Model
(File No. E41643)
Contact form
Coil ratings
G5LE
SPDT-NO (1a)
SPDT (1c)
5 to 24 VDC
G5LE-E
CSA Certified:
Model
10 A, 250 VAC (general use) at 40°C
8 A, 30 VDC (resistive load) at 40°C
TV-3 (N.O only) at 40°C
13 A, 120 VAC, (resistive load) (NO only) at 85°C
10 A, 250 VAC, (general use) at 40°C
TV-8 (NO only) at 40°C
16 A, 250 VAC, (general use) (NO only) at 40°C
12 A, 250 VAC, (general use) (NC only) at 40°C
Number of test
operations
6,000
25,000
30,000
25,000
30,000
(File No. LR31928)
Contact form
Coil ratings
G5LE
SPDT-NO (1a)
SPDT (1c)
5 to 24 VDC
G5LE-E
VDE EN/IEC Certified:
G
5
L
E
Contact ratings
10 A, 250 VAC (general use) at 40°C
8 A, 30 VDC (resistive load) at 40°C
TV-3 (N.O only) at 40°C
13 A, 120 VAC, (resistive load) (NO only) at 85°C
10 A, 250 VAC, (general use) at 40°C
TV-8 (NO only) at 40°C
16 A, 250 VAC, (general use) (NO only) at 40°C
12 A, 250 VAC, (general use) (NC only) at 40°C
Number of test
operations
6,000
25,000
30,000
25,000
30,000
(Certificate No. 6850)
Model
Contact form
Coil ratings
G5LE
G5LE-E
SPDT-NO (1a)
SPDT (1c)
5, 12, 24 VDC
TÜV EN/IEC Certified:
Contact ratings
Contact ratings
10 A, 250 VAC (cosφ = 1) 85°C
16 A, 250 VAC (cosφ = 1) (NO only), 1s ON/5s OFF, 85°C
Number of test
operations
50,000
(Certificate No. R50158258)
Model
Contact form
Coil ratings
G5LE
SPDT-NO (1a)
SPDT (1c)
5, 12, 24 VDC
Contact ratings
2.5 A, 250 VAC (cosφ = 0.4) 85°C
10 A, 250 VAC (resistive load) at 85°C
8 A, 30 VAC (resistive load) at 40°C
Number of test
operations
100,000
50,000
100,000
■Precautions
• Please refer to “PCB Relays Common Precautions” for correct use.
Please check each region's Terms & Conditions by region website.
OMRON Corporation
Electronic and Mechanical Components Company
Regional Contact
Americas
https://www.components.omron.com/
Asia-Pacific
https://ecb.omron.com.sg/
Korea
https://www.omron-ecb.co.kr/
Europe
http://components.omron.eu/
China
https://www.ecb.omron.com.cn/
Japan
https://www.omron.co.jp/ecb/
© OMRON Corporation 2007-2018 All Rights Reserved.
In the interest of product improvement, specifications are subject to change without notice.
4
Cat. No. K100-E1-08
0318(0207)(O)